Pellet Stoves Control System
1993-V1.00
The control card is designed for adjustable dry-type Pellet Stoves, depending on the pellet and chimney type. The built-in chimney fan provides air suction at the determined RPM value. By adjusting the room fan speed, it provides hot air flow to the environment. The 5-level pellet loading time can be adjusted. With the weekly and daily programming feature, the Pellet Stove can be programmed to automatically turn on and off on the desired day and time. It provides user convenience with German, English, French, and Italian language options. The pre-loading function allows pellet loading into the combustion chamber for a specified time while the stove is closed. The Stand-By mode provides users with an economic usage feature. There are 7 alarm conditions for the stove’s full and safe operation. The alarms are recorded in the alarm memory and shown to the user.
Related Products
Fields of Application
- Dry-type Pellet Stoves
- Pellet Burning Systems
Main Features
- Pellet loading (level) adjustment
- Room fan and chimney fan speed adjustment
- Room temperature adjustment
- Ambient and chimney gas temperature sensors
- Economy mode
- 7 different alarm conditions and alarm memory record
- Pellet type selection
- Chimney type selection
- Wired and wireless parameter loading
- Adjustable weekly plan
- 4 language options
- IR remote control
- Computer interface to monitor parameter settings, weekly plan, and real-time status
Technical Specifications
Input Voltage | 230V~ 50Hz |
Power Consumption | ≤ 2.6 VA |
Fuse | 5A Delay |
Flame Detection | K Type Thermocouple |
Storage Temperature | -20°C … +80°C |
Operating Temperature | -10°C … +60°C |
Connections | Power: 3P MSTBA Phoenix
Igniter: 2P MSTBA Phoenix AC Motor Output: 6P MSTBA Phoenix (Chimney Fan, Stoker, Room Fan, Prostat, Limit Thermostat) RPM: 3P MC Phoenix Display: 16P Box Header K Type Thermocouple: 2P MC Phoenix NTC: 2p MC Phoenix |
Electrical Values | CMC Filter: 1125uH 1.8A
Relay: 5A 12V Triac: 4A 600V Transformer: 230/12V 2.6VA |
Alarm Conditions | Chimney Gas Temperature Alarm
Excessive Chimney Gas Temperature Alarm Chimney Fan RPM Alarm Ignition Error Alarm Pellet Shortage Alarm Excessive Temperature Thermal Safety Alarm Pressure Loss Error Alarm |
Features | Computer Interface IR Remote Control |
Standards and Regulations
EN 55011, EN 61000-3-2, EN 61000-4-2/4/5/6/8/9/11